Mangla Rubber Industries logo

Technical

What Hoses Are Used in Green Hydrogen Plants and What Safety Requirements Apply?

18 September 20269 min read
Industrial gas pipework of the kind connected by hydrogen transfer hoses in a green hydrogen plant

Photo by Victor on Unsplash

India’s National Green Hydrogen Mission has set the country on course to become a major producer of hydrogen made from renewable electricity. Electrolyser plants are being built in Gujarat, Odisha, Tamil Nadu and Rajasthan, and pilot projects are under way at refineries, fertiliser units and steel plants. Every one of these facilities depends on flexible connections between fixed pipework and equipment that moves, vibrates or must be isolated for maintenance. Selecting hydrogen transfer hoses and the supporting fluid hoses for these plants is a task that combines conventional hose engineering with the specific hazards of hydrogen.

Hydrogen is the smallest molecule, it burns with an almost invisible flame, and it ignites with a fraction of the energy needed for petrol vapour. These properties change how hose is specified, installed and inspected. This guide explains which hoses are used across a green hydrogen plant, what makes hydrogen transfer hoses different from ordinary gas hose, and which safety requirements Indian plant engineers and EPC contractors need to meet.

What Are Hydrogen Transfer Hoses?

Hydrogen transfer hoses are flexible hose assemblies designed to carry gaseous hydrogen between equipment without leakage, permeation or material degradation. Because hydrogen permeates through most elastomers and embrittles many steels, a hydrogen hose is not simply a chemical hose with a different label. Common constructions are a PTFE or specialised polymer liner with stainless steel wire braid reinforcement, or a fully metallic corrugated stainless steel hose with braid, with end fittings selected for hydrogen compatibility.

In a green hydrogen plant the hydrogen lines are only part of the picture. The balance of plant handles water, electrolyte, oxygen, nitrogen, cooling fluids and compressed air, each with its own hose requirement:

  • Hydrogen product gas hose — low-permeation liner, stainless braid, static-dissipative construction, rated for the pressure after the electrolyser or compressor
  • Demineralised water feed hose — non-contaminating tube such as EPDM or PTFE so that ions are not leached into the feed water
  • Electrolyte hose — for alkaline electrolysers, chemical resistant hose rated for potassium hydroxide solution at operating temperature
  • Oxygen service hose — oxygen-compatible, oil-free construction on the oxygen side of the stack
  • Nitrogen purge hose — general industrial gas hose used to inert equipment before maintenance
  • Cooling water and glycol hose — EPDM hose for stack, rectifier and compressor cooling loops
  • Compressed air hose — for instrument air and pneumatic valves

Why Hydrogen Is Different from Other Gases

Plant engineers who have handled natural gas, LPG or industrial gases may assume that the same hoses will serve for hydrogen. Three properties of hydrogen make that assumption unsafe.

Permeation

Hydrogen molecules pass through rubber and many plastics at rates far higher than methane or air. A conventional rubber gas hose will slowly release hydrogen through its wall, creating a flammable atmosphere in an enclosed space even when there is no visible leak. Hydrogen hoses therefore use liners with very low permeability, such as PTFE or specialised polymers, or all-metal construction, and are often specified with a permeation limit as part of the datasheet.

Embrittlement

Hydrogen diffuses into some steels and reduces their ductility, a process known as hydrogen embrittlement. High-strength carbon steels and certain martensitic stainless grades are particularly affected. Braid wire, end fittings and adapters in hydrogen service are usually specified in austenitic stainless steel grades with proven hydrogen compatibility, and plated carbon steel hydraulic fittings must not be substituted.

Flammability and Ignition

Hydrogen burns in air across a wide concentration range and can be ignited by static discharge from a flowing gas stream. Hoses in hydrogen service must be electrically continuous from end to end and bonded to earth so that static cannot accumulate. The flame is nearly invisible in daylight, so leak detection relies on instruments rather than sight, and hose routing should keep assemblies away from ignition sources and out of enclosed spaces where gas can collect.

Where Hoses Are Used in a Green Hydrogen Plant

Following the process from water intake to hydrogen storage shows where flexible connections are needed and what each one must withstand:

  • Water treatment — raw water and demineralised water hoses connecting reverse osmosis and polishing units to the feed tank; the priority is non-contamination rather than pressure
  • Electrolyser stack — electrolyte circulation on alkaline systems, or demineralised water circulation on PEM systems; hoses see continuous flow at 60 to 90°C and must tolerate the chemistry for years
  • Gas separation and drying — hydrogen and oxygen leave the stack saturated with water; hoses on separators, coolers and dryers handle wet gas and condensate
  • Compression — reciprocating or diaphragm compressors vibrate, and flexible hydrogen hose isolates the compressor from fixed pipework; this is the highest pressure and highest risk hose duty in the plant
  • Storage and dispensing — tube trailers, storage vessels and fuelling dispensers use hydrogen hose assemblies rated for the storage pressure, often 350 or 700 bar for vehicle fuelling
  • Utilities — cooling water, instrument air and nitrogen purge hoses throughout the plant

For the chemical resistant hose used on the electrolyte and water treatment side, our guide to chemical resistant rubber hoses and their uses covers compound selection. Where PTFE is specified for the liner, our article on where PTFE Teflon hose is used and why it outperforms rubber explains the material.

Safety Requirements for Hydrogen Hose Assemblies

Hydrogen hose is regulated more closely than most industrial hose. The following requirements should be treated as a minimum in any Indian green hydrogen project:

  • Standard compliance — hoses for hydrogen fuelling are covered by ISO 19880-5, and compressed gas hose assemblies by related ISO and national standards; the datasheet should state the standard the assembly is tested to
  • Pressure rating — working pressure with a burst safety factor of at least 4:1, and impulse testing where the hose is on a compressor or dispenser
  • Permeation limit — a stated maximum hydrogen permeation rate for the liner material
  • Electrical continuity — resistance between end fittings low enough to dissipate static, verified at manufacture and at periodic inspection
  • Material certification — mill certificates for braid and fittings confirming hydrogen-compatible stainless grades
  • Hazardous area suitability — hose covers and any markings suitable for the zone classification around the equipment
  • Traceability — each assembly serial numbered, with test records and an inspection schedule
  • Statutory approval — storage and handling of compressed hydrogen in India falls under the Gas Cylinder Rules and Static and Mobile Pressure Vessels Rules administered by the Petroleum and Explosives Safety Organisation

Details of the licensing framework for compressed gas storage and handling are published by the Petroleum and Explosives Safety Organisation (PESO), Government of India. The wider set of safety standards that apply to any industrial hose is covered in our article on the safety standards every industrial hose pipe must meet.

Installation, Inspection and Replacement

A hydrogen hose that meets every specification will still fail if it is installed with a twist, bent below its minimum radius at the compressor flange or left resting on a hot surface. Assemblies should be installed with the lay line straight, supported so that the weight of fittings does not hang on the hose, and routed so that a leak would disperse upward into open air rather than into an enclosure.

Inspection should be scheduled rather than left to chance. Check for cover damage, braid corrosion, fitting deformation and any change in electrical continuity at each interval, and leak test with a hydrogen detector after every reconnection. Most operators set a fixed replacement interval for hydrogen hose assemblies regardless of visual condition, because internal liner damage cannot be seen. The balance of plant hoses on water, electrolyte and cooling duties follow a conventional inspection routine, but a failure there can still shut down the electrolyser, so they should be included in the same maintenance plan.

Choose Hoses for Hydrogen Plants from Mangla Rubber Industries

Mangla Rubber Industries manufactures PTFE Teflon hoses, chemical resistant hoses, EPDM water and coolant hoses and pneumatic hoses for electrolyser plants, hydrogen project EPC contractors and equipment OEMs in India. Our technical team works with project engineers to match each balance-of-plant duty to the correct construction, and to identify where a hydrogen-specific certified assembly is required rather than a general industrial hose.

Share the fluid, pressure, temperature and installation details for each connection in your plant, and we will recommend the correct hose and fittings. To discuss a hydrogen or electrolyser project, contact Mangla Rubber Industries.

Conclusion

A green hydrogen plant needs a wide range of hoses, from demineralised water and electrolyte lines to high-pressure compressor connections. Hydrogen transfer hoses must control permeation, resist embrittlement, dissipate static and meet the standards and statutory requirements that apply to compressed hydrogen in India, while the supporting water, chemical and utility hoses must be specified with the same care so that a minor leak does not stop the electrolyser. Treating hose selection as part of the plant safety case, rather than as a procurement detail, is the foundation of a reliable hydrogen facility.

Frequently Asked Questions

Can ordinary rubber gas hose be used for hydrogen?

No. Hydrogen permeates through rubber far faster than natural gas or LPG, so a conventional rubber gas hose will release hydrogen through its wall. Hydrogen service needs a low-permeation liner such as PTFE or an all-metal construction, with hydrogen-compatible fittings.

What pressure do hydrogen hoses need to handle?

It depends on the location. Hoses after an electrolyser typically see up to a few tens of bar, while compressor discharge, storage and fuelling hoses may operate at 350 or 700 bar. Each assembly must be rated for its own duty with a 4:1 burst safety factor.

Why must hydrogen hoses be electrically conductive?

Flowing hydrogen can generate static charge, and hydrogen ignites with very little energy. A hose with electrical continuity between its end fittings, bonded to earth, prevents static from building up and discharging as a spark.

Which hose is used for electrolyte in an alkaline electrolyser?

Alkaline electrolysers circulate potassium hydroxide solution at elevated temperature. A chemical resistant hose with an EPDM or similar alkali-resistant tube is normally specified, with compatibility confirmed for the concentration and temperature in use.

Which Indian authority regulates hydrogen storage and handling?

The Petroleum and Explosives Safety Organisation (PESO) administers the rules covering compressed gas cylinders and pressure vessels, including hydrogen. Plant designs, storage and transport arrangements need approval under that framework.