SAE 100 R1 vs R2 Pressure Rating Chart (PSI and Bar)

Quick answer: SAE 100 R1 hose has one wire braid and a maximum working pressure of 3,250 psi (224 bar) at 1/4″ bore, falling to 375 psi (26 bar) at 2″. SAE 100 R2 hose has two wire braids and roughly double the rating — 5,800 psi (400 bar) at 1/4″, falling to 1,125 psi (78 bar) at 2″. Both carry a 4:1 minimum burst-to-working-pressure safety ratio.
SAE 100 R1AT pressure rating chart
| Bore (inch) | Bore (mm) | Dash | Working pressure (psi) | Working pressure (bar) | Minimum burst (psi) |
|---|---|---|---|---|---|
| 1/4″ | 6.4 | -04 | 3,250 | 224 | 13,000 |
| 5/16″ | 7.9 | -05 | 2,750 | 190 | 11,000 |
| 3/8″ | 9.5 | -06 | 2,250 | 155 | 9,000 |
| 1/2″ | 12.7 | -08 | 2,000 | 138 | 8,000 |
| 5/8″ | 15.9 | -10 | 1,500 | 103 | 6,000 |
| 3/4″ | 19.0 | -12 | 1,250 | 86 | 5,000 |
| 1″ | 25.4 | -16 | 1,000 | 69 | 4,000 |
| 1-1/4″ | 31.8 | -20 | 625 | 43 | 2,500 |
| 1-1/2″ | 38.1 | -24 | 500 | 34 | 2,000 |
| 2″ | 50.8 | -32 | 375 | 26 | 1,500 |
SAE 100 R2AT pressure rating chart
| Bore (inch) | Bore (mm) | Dash | Working pressure (psi) | Working pressure (bar) | Minimum burst (psi) |
|---|---|---|---|---|---|
| 1/4″ | 6.4 | -04 | 5,800 | 400 | 23,200 |
| 5/16″ | 7.9 | -05 | 5,000 | 345 | 20,000 |
| 3/8″ | 9.5 | -06 | 4,800 | 331 | 19,200 |
| 1/2″ | 12.7 | -08 | 4,000 | 276 | 16,000 |
| 5/8″ | 15.9 | -10 | 3,500 | 241 | 14,000 |
| 3/4″ | 19.0 | -12 | 2,750 | 190 | 11,000 |
| 1″ | 25.4 | -16 | 2,250 | 155 | 9,000 |
| 1-1/4″ | 31.8 | -20 | 1,625 | 112 | 6,500 |
| 1-1/2″ | 38.1 | -24 | 1,250 | 86 | 5,000 |
| 2″ | 50.8 | -32 | 1,125 | 78 | 4,500 |
Values are the SAE J517 published maximum working pressures for R1AT and R2AT construction. Always confirm the figure on the manufacturer’s own specification sheet for the hose you are buying.
Need 4,000 psi? Here is the direct answer
4,000 psi (276 bar) is the working pressure of 1/2″ SAE 100 R2AT hose. If you need 4,000 psi at a larger bore, R2 runs out at 3/8″ (4,800 psi) and 1/2″ (4,000 psi) — above 1/2″ you must move to 4-spiral (SAE 100 R12 / 4SP) construction. R1 cannot reach 4,000 psi at any size.
What is the difference between R1 and R2 hydraulic hose?
| SAE 100 R1 | SAE 100 R2 | |
|---|---|---|
| Reinforcement | One high-tensile steel wire braid | Two high-tensile steel wire braids |
| Working pressure | Medium — 375 to 3,250 psi | High — 1,125 to 5,800 psi |
| Pressure vs R1 | Baseline | Approximately 1.8× to 2× higher |
| Flexibility | More flexible, tighter bend radius | Stiffer, larger bend radius |
| Weight | Lighter | Heavier |
| Cost | Lower | Higher |
| EN equivalent | EN 853 1SN | EN 853 2SN |
| Typical use | Tractor lift lines, return lines, low-shock circuits | Excavator and loader boom circuits, press lines, high-shock duty |
Both use the same NBR oil-resistant tube and the same synthetic rubber cover. The only structural difference is the number of wire braids, and that difference is where the pressure capability and the stiffness both come from.
The practical decision rule: if your system peak pressure exceeds 60% of the R1 rating for your bore, specify R2. Hydraulic circuits generate pressure spikes well above the gauge reading, and R1 running near its ceiling fails by impulse fatigue long before it fails by burst.
Why does working pressure drop as the hose gets bigger?
Because hoop stress in a pressure vessel rises with diameter. For the same wall and the same wire, doubling the bore roughly halves the pressure the hose can contain. This is why a single “3,000 psi hose” claim with no bore stated is meaningless — and a reliable sign that you are reading a trader’s listing rather than a manufacturer’s specification.
What does the 4:1 safety ratio mean?
SAE J517 requires hydraulic hose to have a minimum burst pressure of four times the maximum working pressure. A 1/2″ R2 hose rated at 4,000 psi must survive 16,000 psi before bursting.
The margin is not spare capacity you may use. It covers pressure spikes, temperature derating, ageing of the compound, assembly variation and crimp tolerance. Operating a hose above its rated working pressure consumes the safety factor that keeps it from killing someone when it bursts.
Two derating rules to apply on top of the chart:
- Temperature. Above +70 °C, derate working pressure. At +100 °C, assume roughly 50% of the rated figure for a standard NBR-tube hose. See how much heat a hydraulic hose can withstand.
- Impulse duty. For high-cycle circuits, the braided ratings above are a burst figure, not a fatigue figure. High-impulse applications need spiral construction — see 2-wire vs 4-spiral vs 6-spiral hose.
Which should you buy?
- R1 — tractor trolley lift lines, hydraulic return lines, steering circuits, low-shock machinery under 2,000 psi at your bore. Full specification in our SAE 100 R1 guide.
- R2 — backhoe loader and excavator boom circuits, presses, injection moulding, any high-shock circuit above 2,000 psi. Full specification in our SAE 100 R2 guide.
- 4SP / 4SH spiral — mining, drilling, harvesters and anything with continuous high-frequency impulse. See the combine harvester 4SP hose guide.
- R6, R7, R4 — low pressure, suction and thermoplastic alternatives. Covered in SAE 100 R4, R6, R7, R12 and R16 compared.
Mangla Rubber Industries manufactures both SAE 100 R1 and SAE 100 R2 hose at its Ghaziabad plant and has supplied Indian hydraulics since 1983. See the range or send your pressure and bore requirement — +91 88007 72816.
Frequently Asked Questions
What is the pressure rating of SAE 100 R1 hose?
SAE 100 R1 working pressure ranges from 3,250 psi (224 bar) at 1/4″ bore down to 375 psi (26 bar) at 2″ bore. Minimum burst pressure is four times the working pressure in every size, as required by SAE J517.
What is the pressure rating of SAE 100 R2 hose in bar?
SAE 100 R2 working pressure in bar: 400 bar at 1/4″, 345 at 5/16″, 331 at 3/8″, 276 at 1/2″, 241 at 5/8″, 190 at 3/4″, 155 at 1″, 112 at 1-1/4″, 86 at 1-1/2″ and 78 bar at 2″ bore.
What is the difference between R1 and R2 hose?
R1 has one steel wire braid; R2 has two. R2 therefore carries roughly double the working pressure of R1 at the same bore, but is stiffer, heavier and more expensive. Both use the same oil-resistant nitrile tube and weather-resistant cover.
Which hydraulic hose is rated for 4000 psi?
1/2″ SAE 100 R2AT is rated at 4,000 psi (276 bar). For 4,000 psi at bores above 1/2″, use 4-spiral construction such as SAE 100 R12 or EN 856 4SP. SAE 100 R1 does not reach 4,000 psi at any size.
Why does hydraulic hose pressure rating decrease with size?
Hoop stress in any pressurised cylinder increases with diameter, so the same reinforcement contains less pressure in a larger bore. Doubling the bore roughly halves the working pressure, which is why a pressure rating quoted without a bore size is not usable.
Can I run a hydraulic hose at its maximum rated pressure continuously?
It is better not to. The rated working pressure assumes ambient temperature and moderate cycling. Above +70 °C, derate it; in high-impulse service, use spiral hose instead. As a working rule, if system peaks exceed 60% of the rated figure, move up a grade.